Ignalina Reactor Incidents Table
This is an archived page. Please visit the new Lithuania country profile.

Lithuania: Ignalina Reactor Incidents Table

(Click here to view the NIS Nuclear Profiles criteria for reporting reactor developments.)
 
Unit
Date
Problem
INES
Radiation
Injury
Shut down?
Source
2 4/2/98 Leak in cooling system 0 N N 27 days Interfax, 5/5/98
1 3/03/98 Operator error causes unit to shutdown
0
N
N
2 Days Baltic News Service, 3/5/98
2 11/04/96 Automatically shut down when 3rd turbo-generator turned off
0
N
N
--
Baltic News Service, 11/4/96
1 9/10/96 Oil leak
0
N
N
2 days The Baltic Times, 9/12-18/96 p.3
1 8/27/96 Water leak in cooling system
0
N
N
1 week  UI Newsbriefing 96.34, 8/21-28/96
-- 8/07/96 Steam discharge
--
N
N
--
Reuter, 8/7/96
-- 7/08/96 Steam supply valve malfunction
--
N
--
Few hours Itar-Tass, 7/9/96, FBIS-SOV-96-133
-- 7/05/96 Steam supply valve malfunction
--
N
--
Few hours Itar-Tass, 7/9/96, FBIS-SOV-96-133
2 5/14/96 Main circulation pump shut down 
0
N
N
No, dropped to 60% for 12 hours Baltic News Service Daily Report, 5/15/96
1 2/09/96 Electric cable damage caused shutdown
0
N
N
2 1/2 days  Baltic News Service Daily Report, 2/12/96
2 1/25/96 Repairs causes accidental shut down
0
N
N
3 hours Baltic News Service Daily Report, 1/25/96
2 1/07/96 Leak in cooling system pipes
0
N
Approximately 5 days Baltic News Service Daily Report, 1/8/96
-- 11/30/95 Radiation escape
1 or 2*
Y
--
--
Baltic News Service Daily Report, 1/8/96
2 11/23/95 Shut down after security alarm malfunction
0
N
N
2 days Baltic News Service Daily Report, 11/27/95
2 11/22/95 --
0
N
N
No, reduced capacity for a few hours Segodnya, 11/25/95, p.5
1 11/12/95 Fire in machine room
0
N
N
24 hours RFE/RL Digest, No. 222, Part II, 11/14/9
2 11/95 12 tons of water released from emergency core cooling tanks
1
--
--
-- Soviet Plant Source Book, 1/96, p. 196
-- 8/95 Power supply accidentally cut off
1
--
--
No, reduced power supply Soviet Plant Source Book, 1/96, p. 197
1 11/03/94 Coolant leak
0
--
--
temporarily Nucleonics Week, 11/10/94, pp. 7-8
1 8/09/94 Generator stopped working
--
N
--
24 hours Russia & CIS Today, 8/10/94, p. 6
-- 7/11/94 Control rod switch improperly installed
1
--
--
--, replaced switch Soviet Plant Source Book, 1/96, p. 196
-- 2/22/94 Radiated steam escaped
1
Y
--
-- UPI, 2/25/94
-- 2/94 Fire protection equipment freezes
1
--
--
-- Soviet Plant Source Book, 1/96, p. 196
-- 2/94 Damaged sealing gaskets
1
--
--
temporarily Soviet Plant Source Book, 1/96, p. 196
1 1/94 Control board fire
0
--
--
temporarily Soviet Plant Source Book, 1/96, p. 196
1 1/94 Faulty weld releases contaminated water
--
--
--
temporarily Soviet Plant Source Book, 1/96, p. 196

-- Information unavailable.
* There was a dispute over the INES rating of this incident. VATESI states that the incident rated a 2.

Last updated 10 February 1999
For more recent updates, see the Ignalina NPP Developments 1998-Present file.

Comments or questions? Contact Kenley Butler at MIIS CNS: Kenley.Butler@miis.edu
 

CNSThis material is produced independently for NTI by the Center for Nonproliferation Studies at the Monterey Institute of International Studies and does not necessarily reflect the opinions of and has not been independently verified by NTI or its directors, officers, employees, agents. Copyright © 2003 by MIIS.

HOME  |  CONTACT US  |  SITE MAP